Thank you!
We will contact you shortly
S7 takes just half of a suitcase for the cabin to fly!
Travel friendly
the lightest CCR in the world – just 5 kg!
Compact
the smallest CCR in the world – just the size of 2L tank!mCCR with 1.9 kg of the scrubber!
Multifunctional
from Rec to the top SpeleoDiving expeditions!
Sidemount
the most flexible tool for any kind of diving and emergencies!
s7 is a multifunctional tool for any type of diving!
Rec diving
one tank plus s7 on the side with 1L O2 on the unit
Twins diving
s7 on the side with 2L O2 on the unit
Sidemount Diving
SM tanks and 2L O2 tank on the butt or 3L tank as stage
Toddy Style SM Diving
2-3L Diluent and O2 tanks are on the backplate
Bailout CCR diving
any configuration with s7 as bailout CCR
Dual CCR diving
two s7 CCRs
Serious deep diving
s7 as Oxygen CCR
Sump diving
s7 as a game changer
Speleo diving
difficult logistics is not so difficult with s7
Nothing has ever been smaller before!
The hight is like 2 L tank (on the photo), the diameter is like 3 L tank
EASY!
- exhaled gas goes to the single counterlung
- diluent and O2 are added by diver through MAV to the counterlung
- gas goes through the scrubber, mixing
- CO2 removes in the scrubbercells measure the ppO2 level which is shown on the monitor
- gas goes to the DSV to be inhaled
s7 is a multifunctional tool for any type of diving!
The counterlung has:- dump valve allows automatic or manual removal of gas from the counterlung- anti-collaps system allows preventing the collapse of the counterlung- water trap space prevents water from coming to the scrubber to dissolve the absorbent
- capacity of the counterlung – 5.4L- volume of the water trap – 1 L- counterlung is designed to collect water in the lowest place - OPV valve - to remove water quickly- "motorcycle" fabric protection. Soft and robust
The position of the counterlung on the body is between the classical chestmount and sidemount, close to the body. It gives a diver a fantastic WOB in any body position
The best position of the unit with SideMount harness is a stage-like
- perfect WOB in all possible positions of the body
- control the volume of gas inside more efficiently
- no mount of the unit to pass restrictions
- possibility to give the unit to a buddy in an emergency case
- possibility to take off and leave the unit in a cave in case of a total flood in an emergency case
Use s7 as a stage like with BackMount! What can be easier?
- s7 works perfectly with one tank or a double tank in Backmount
- It is reasonable to keep a 1-2L O2 tank on the body of the unit
Axial scrubber - just 2 minutes to fill out!
- Axial scrubber - the simplest type of scrubbers. No orings – more reliable!
- capacity of the scrubber - 1.9 kg
- time of breathing – up to 4 hours, depending on the condition of diving. In cold water lower 6 degrees, a neoprene sleeve helps to keep the efficiency of the absorbent. s7 is short, and the temperature of the gas drops less than in ”big and long” units!
- difficult speleo logistics? Put 1 kg of absorbent for up to 2 hours of diving to reduce the weight of the CCR
One MAV two gases!
Manual Addition Valve:- supplies diluent and O2 to the looporifice or needle valve is inside- orifice supply 1L O2 per minuteneedle valve has an adjustable tension of the rotation of the valve
O2 MAVmaintains breathable oxygen levelscompensates for metabolic oxygen consumption
Diluent MAVreduces PO₂ if too highmaintains loop volume during descentflushes the loopprovides breathable gas in emergencies
One MAV two gases!
To connect off-board gas, any type of connectors can be used. In basic configuration, S7 goes with inflator connector for Dil and 9/16 male connector for Oxy
For serious diving in case if you need to change gases underwater we recommend to use Swagelock QC4 for Oxygen and QC6 for Diluent:- one type of connector, but with different diameters. The same muscle memory, but no possibility of making a fatal mistake and connecting the wrong gas- big connectors – easy work even with thick gloves- minimum water goes inside when the connection does underwater – minimum risk of water with salt or sediment going inside of MAV to damage it
Several options!
- no cablesa Halcyon transmitter in the s7 head. No cables, wireless connection to a Halcyon computer and HUD
- one AK4 cableTo connect a Shearwater computer
- one AK4 cable and Halcyon transmitterTo connect a Shearwater computer and a Halcyon computer and HUD at the same time
- 2 AK4 cablesTo connect a Shearwater computer and a Shearwater NERD
official Partners
Galvanic or solid cells are good!
s7 uses coaxial connectors on the cellsThey provide a firm connection and high reliability in wet conditions
Any cells (galvanic or solid state) with a coax connector compatible with a monitor can be used. It should be three cells R22SMB type
Connect the calibration cover to the head and save Oxygen when calibrating. "Fild" method is also good
the smallest and lightest DSV on the market!
S7CCR characteristics
characteristics
characteristics
characteristics
CONTROLLER
Primary: Optional Shearwater Petrel 3 or HW Diving OSTC+ (4-PIN AK)Redundant: NOSecondary electronics/PPO2 reader: NO
CONTROLLER
characteristics
Primary: Optional Shearwater Petrel 3 or HW Diving OSTC+ (4-PIN AK)Redundant: NOSecondary electronics/PPO2 reader: NO
SCRUBBER
Type: Axial
Volume: 1.9 kg
Monitoring: NO
Duration CE-CO2 1.6L/m 5mb bypass: 4 hours typical
SCRUBBER
characteristics
Type: Axial
Volume: 1.9 kg
Monitoring: NO
Duration CE-CO2 1.6L/m 5mb bypass: 4 hours typical
LOOP
WOB-CE 100m test, trimix, horizontal: N/AWOB-CE 40m test, air, vertical: N/AActive loop volume CE test: N/ACounterlung volume: 5.0 LBack-mounted counterlung: NOFront-mounted counterlungs: YES, at side towards the chestDetachable counterlungs (without unit disassembly): YESOxygen injection side: exhaleLoop direction: Left to right (can be changed to wear unit on theleft)Automatic diluent valve (ADV): YES, optionalDiluent shut-off valve: YES, with ADV optionBailout valve (BOV): NOMouthpiece retaining strap: third party optionFlood Resistant: Water trap in exhale lung; drain OPV in exhalelung
LOOP
characteristics
WOB-CE 100m test, trimix, horizontal: N/AWOB-CE 40m test, air, vertical: N/AActive loop volume CE test: N/ACounterlung volume: 5.0 LBack-mounted counterlung: NOFront-mounted counterlungs: YES, at side towards the chestDetachable counterlungs (without unit disassembly): YESOxygen injection side: exhaleLoop direction: Left to right (can be changed to wear unit on theleft)Automatic diluent valve (ADV): YES, optionalDiluent shut-off valve: YES, with ADV optionBailout valve (BOV): NOMouthpiece retaining strap: third party optionFlood Resistant: Water trap in exhale lung; drain OPV in exhalelung
HEAD & SENSORS
Plug and play head components-user replaceable: YES
User upgradeable firmware: YES
Number of O2 cells-options: 3
Number of solenoids: 0
Means of O2 addition: Needle valve dual MAV, optional CMF
orifice dual MAV
Solid-state O2 sensor(s): N/A
Independent secondary O2 reading: N/A
Oxygen cell tester (>1bar) - (built-in or add-on): NO
Helium sensors: NO
Gaseous CO2 sensors: NO
Dual computers: NO
Independent electronics: N/A
CCR bailout mode: YES
Battery type: No batteries required
Battery life (dive time): N/A
HEAD & SENSORS
characteristics
Plug and play head components-user replaceable: YES
User upgradeable firmware: YES
Number of O2 cells-options: 3
Number of solenoids: 0
Means of O2 addition: Needle valve dual MAV, optional CMF
orifice dual MAV
Solid-state O2 sensor(s): N/A
Independent secondary O2 reading: N/A
Oxygen cell tester (>1bar) - (built-in or add-on): NO
Helium sensors: NO
Gaseous CO2 sensors: NO
Dual computers: NO
Independent electronics: N/A
CCR bailout mode: YES
Battery type: No batteries required
Battery life (dive time): N/A
DISPLAYS & WARNINGS
Heads up display: NOBuddy display: NOOther active warning devices: Handset vibrationNear eye computer (HUD): NO
DISPLAYS & WARNINGS
characteristics
Heads up display: NOBuddy display: NOOther active warning devices: Handset vibrationNear eye computer (HUD): NO
HANDSET
Number of handsets: 1Pressure reading (air integration): YESBluetooth: YESDigital compass: YESMulti-language interface: YES
HANDSET
characteristics
Number of handsets: 1Pressure reading (air integration): YESBluetooth: YESDigital compass: YESMulti-language interface: YES
BUOYANCY
BCD lift (kg): User supplied sidemount BCDDrop weights: NO
BUOYANCY
characteristics
BCD lift (kg): User supplied sidemount BCDDrop weights: NO
CYLINDERS
Cylinder options: 1 L / 1.5 L / 2 L
Onboard multi-diluent tank option: NO
Offboard gas feed: YES
CYLINDERS
characteristics
Cylinder options: 1 L / 1.5 L / 2 L
Onboard multi-diluent tank option: NO
Offboard gas feed: YES
FORM FACTOR
Backmount conversion: NOTravel/mini version: YESStand: NO
FORM FACTOR
characteristics
Backmount conversion: NOTravel/mini version: YESStand: NO
SERVICE & SUPPORT
Supplied ready to dive (cells, tanks, valves) – geo specific: N/A
Warranty (months): 24
Worldwide service/support: European service support
Recommended service interval: annually
Return to HQ or service center: NO, complete unit is user
serviceable
Cost of service: N/A
SERVICE & SUPPORT
characteristics
Supplied ready to dive (cells, tanks, valves) – geo specific: N/A
Warranty (months): 24
Worldwide service/support: European service support
Recommended service interval: annually
Return to HQ or service center: NO, complete unit is user
serviceable
Cost of service: N/A
SHIPPING & ORDERING
Weight ready to dive: approx. 4 kg empty / approx. 6 kg ready todiveOrigin: UK design, UK and Germany manufacture
SHIPPING & ORDERING
characteristics
Weight ready to dive: approx. 4 kg empty / approx. 6 kg ready todiveOrigin: UK design, UK and Germany manufacture
s7 is a GAME CHANGER!
- the handle to carry the unit- upper boltsnap for vertical transportation- s7 shield for easy carrying and even nicer looking. Very good for boat diving!
Enter your email and get our latest news about our products and services.